[1] 邱雪梅, 黄译丹, 李雍, 等.复合材料杆塔研究现状及发展趋势 [J].电气技术, 2017(9): 1-3+9.DOI:  10.3969/j.issn.1673-3800.2017.09.006.

QIUX M, HUANGY D, LIY, et al.Composite tower research status and development trend [J].Electrical Engineering, 2017(9): 1-3+9.DOI:  10.3969/j.issn.1673-3800.2017.09.006.
[2] 阮少林, 陈国栋.500 kV复合材料单回路塔新型输配电分析 [J].云南电力技术, 2018, 46(6): 134-136.DOI:  10.3969/j.issn.1006-7345.2018.06.034.

RUANS L, CHENG D.Comparison and analysis of 500 kV composite materialSingle loop tower [J].Yunnan Electric Power, 2018, 46(6): 134-136.DOI:  10.3969/j.issn.1006-7345.2018.06.034.
[3] 胡超, 冯衡, 徐彬.750 kV输电线路复合材料横担塔的适用性研究 [J].电力勘测设计, 2016(1): 65-71.DOI:  10.3969/j.issn.1671-9913.2016.01.018.

HUC, FENGH, XUB.Research on the applicability of composite cross arm tower for 750 kV transmission line [J].Electric Power Survey & Design, 2016(1): 65-71.DOI:  10.3969/j.issn.1671-9913.2016.01.018.
[4] 左玉玺, 王虎长, 朱永平, 等.750 kV输电线路复合横担设计研究 [J].电网与清洁能源, 2013, 29(1): 1-8.DOI:  10.3969/j.issn.1674-3814.2013.01.001.

ZUOY X,WANGH C, ZHUY P, et al.Research on the design of composite cross arm for 750 kV transmission line [J].Power System and Clean Energy, 2013, 29(1): 1-8.DOI:  10.3969/j.issn.1674-3814.2013.01.001.
[5] 柏晓路, 雷雨泽, 刘文勋, 等.1 000 kV交流特高压输电线路复合横担应用研究 [J].电力勘测设计, 2020(增刊1): 120-126. DOI:  10.13500/j.dlkcsj.issn1671-9913.2020.S1.022.

BAIX L, LEIY Z, LIUW X, et al.Research on the application of composite cross arm for 1 000 kV ultra high voltage AC transmission line [J].Electric Power Survey & Design, 2020(Supp.1): 120-126. DOI:  10.13500/j.dlkcsj.issn1671-9913.2020.S1.022.
[6] 杜颖.强风地区500 kV同塔双回输电线路复合材料横担杆塔应用设计研究 [J].科技创新与应用, 2020(5):85-86.

DUY.Application design of composite cross arm pole and tower for 500 kV double circuit transmission line on the same tower in strong wind area [J].Technology Innovation and Application, 2020(5): 85-86.
[7] 李子扬, 张思祥, 张丽娟, 等.新型复合横担在1 000 kV特高压输电铁塔的应用 [J].山东电力技术, 2017(9):56-61.DOI:  10.3969/j.issn.1007-9904.2017.09.011.

LIZ Y, ZHANGS X, ZHANGL J, et al.Application of the new composite cross arm load in 1 000 kV transmission tower [J].Shandong Electric Power, 2017, 44(9): 52-59.DOI:  10.3969/j.issn.1007-9904.2017.09.011.
[8] 张禄琦, 郝阳, 李喜来, 等.特高压直流杆塔新型复合横担布置研究 [J].电网与清洁能源, 2019, 35(2):5 8-62+68.DOI:  10.3969/j.issn.1674-3814.2019.02.009.

ZHANGL Q, HAOY, LIX L, et al.Study on the layout of new composite cross arms for the UHV DC tower [J].Advances of Power System & Hydroelectric Engineering, 2019, 35(2): 58-62+68.DOI:  10.3969/j.issn.1674-3814.2019.02.009.
[9] 胡良全.电力行业用复合材料的发展 [J].玻璃钢/复合材料, 2012(3): 91-93.DOI:  10.3969/j.issn.1003-0999.2012.03.020.

HUL Q.Development of composites for power industry [J].Composites Science and Engineering, 2012(3): 91-93.DOI:  10.3969/j.issn.1003-0999.2012.03.020.
[10] 吴雄, 胡虔, 潘吉林, 等.复合材料杆塔及材料多因子老化特性 [J].高电压技术, 2016, 42(3): 908-913.DOI:  10.13336/j.1003-6520.hve.20160308026.

WUX, HUQ, PANJ L, et al.Aging properties of composite material pole and its materials under multi-factor environment [J].High Voltage Engineering, 2016, 42(3): 908-913. DOI:  10.13336/j.1003-6520.hve.20160308026.
[11] 朱岸明, 杨大渭, 刘云贺, 等.FRP复合材料杆塔横担研究应用现状及分析 [J].电网与清洁能源, 2015, 31(10): 76-82+88.DOI:  10.3969/j.issn.1674-3814.2015.10.015.

ZHUA M, YANGD W, LIUY H, et al.Application and analysis of cross arms made from FRP composite materials in transmission towers [J].Advances of Power System & Hydroelectric Engineering, 2015, 31(10): 76-82+88.DOI:  10.3969/j.issn.1674-3814.2015.10.015.
[12] 林文.基于覆冰地区500 kV输电线路抗冰设计探讨 [J].通讯世界, 2016(9):133-135.DOI:  10.3969/j.issn.1006-4222.2016.09.095.

LINW.Discussion on anti icing design of 500 kV transmission line based on icing area [J].Telecom World, 2016(9): 133-135.DOI:  10.3969/j.issn.1006-4222.2016.09.095.
[13] 肖宇, 杨磊.山区输电线路常规基础造价对比分析 [J].电力勘测设计, 2015(3):74-80.DOI:  10.13500/j.cnki.11-4908/tk.2015.03.018.

XIAOY, YANGL.Comparison on common foundation cost of power transmission line in mountain area [J].Electric Power Survey & Design, 2015(3): 74-80.DOI:  10.13500/j.cnki.11-4908/tk.2015.03.018.