Abstract:
Objective The fan foundation with prestressed anchor bolt type connection design is the mainstream design at present. The mechanical characteristic of the foundation connected by prestressed anchor bolt is a kind of circular load. There is no detailed analysis data to refer to under such mechanical characteristics. The designers often rely on finite element analysis to analyze the structural safety here, but it takes a longer time. This paper aims to quickly calculate the stress value of the core region of the foundation
Method Based on the Mohr-Coulomb theory and elastic mechanics theory, a set of vertical stress calculation formula suitable for the design of the core area of fan foundation was derived in this paper, and compared and verified with the fine finite element analysis results.
Results Comparative results indicate that the formulas derived in this paper demonstrate good accuracy and reliability.