Advanced Search
Yuyan DUAN, Weike LI, Xiaoru FAN, Afeng WU, Peiqiang HUO, . Research on the Number of Mill in 660 MW Super-critical Unit of "W" Flame Furnace[J]. SOUTHERN ENERGY CONSTRUCTION, 2018, 5(1): 127-131. DOI: 10.16516/j.gedi.issn2095-8676.2018.01.022
Citation: Yuyan DUAN, Weike LI, Xiaoru FAN, Afeng WU, Peiqiang HUO, . Research on the Number of Mill in 660 MW Super-critical Unit of "W" Flame Furnace[J]. SOUTHERN ENERGY CONSTRUCTION, 2018, 5(1): 127-131. DOI: 10.16516/j.gedi.issn2095-8676.2018.01.022

Research on the Number of Mill in 660 MW Super-critical Unit of "W" Flame Furnace

  • Relying on one 660 MW super critical "W" flame furnace coal-fired unit project, this article proposed a new proposal on the number of mill in pulverizing system. Through the technology and economic comparations between the general proposal of 6 mills and the new proposal of 4 mills, it was demonstrated that the new proposal of 4 sets double into and out mills is viable on technology, reliable on operation and good on economic benefit. This article proposed the new idea for drawing up the plan on pulverizing system of this type of unit.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return