LI Qian, LIU Junxiang. Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines[J]. SOUTHERN ENERGY CONSTRUCTION, 2016, 3(S1): 107-111. doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023
Citation: LI Qian, LIU Junxiang. Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines[J]. SOUTHERN ENERGY CONSTRUCTION, 2016, 3(S1): 107-111. doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023

Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines

doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023
  • Received Date: 2015-06-11
  • Publish Date: 2020-07-17
  • The analysis on the total electric field under the HVAC-HVDC ajacent-tower hybrid transmission lines plays an important role in evaluating the electromagnetic environment nearby. However, few existing research considers the mutual effect of HVAC-HVDC hybrid transmission lines. This paper which considers the mutual effect calculates the total electric field. By comparing the results generated by the calculation with those in published literature, we consider the program reliable. This paper analyzes the influence of sub-conductor radius, sub-conductor splitting number, weather condition and space arrangement of lines. The results show that the total electric field can be effectively reduced by increasing the radius, increasing the splitting number, using the space arrangement with the positive polar closing to AC line. A significant increase in the total electric field on rainy condition should be given special attention.
  • 通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

Article Metrics

Article views(164) PDF downloads(148) Cited by()

Related

Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines

doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023

Abstract: The analysis on the total electric field under the HVAC-HVDC ajacent-tower hybrid transmission lines plays an important role in evaluating the electromagnetic environment nearby. However, few existing research considers the mutual effect of HVAC-HVDC hybrid transmission lines. This paper which considers the mutual effect calculates the total electric field. By comparing the results generated by the calculation with those in published literature, we consider the program reliable. This paper analyzes the influence of sub-conductor radius, sub-conductor splitting number, weather condition and space arrangement of lines. The results show that the total electric field can be effectively reduced by increasing the radius, increasing the splitting number, using the space arrangement with the positive polar closing to AC line. A significant increase in the total electric field on rainy condition should be given special attention.

LI Qian, LIU Junxiang. Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines[J]. SOUTHERN ENERGY CONSTRUCTION, 2016, 3(S1): 107-111. doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023
Citation: LI Qian, LIU Junxiang. Research on the Total Electric Field Under HVAC-HVDC Ajacent-tower Hybrid Transmission Lines[J]. SOUTHERN ENERGY CONSTRUCTION, 2016, 3(S1): 107-111. doi: 10.16516/j.gedi.issn2095-8676.2016.S1.023

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return