• Peer Review
  • Non-profit
  • Global Open Access
  • Green Channel for Rising Stars
Volume 4 Issue 4
Jul.  2020
Turn off MathJax
Article Contents

Ting ZENG, Xiaoming GAO, Zhe WU, Liangliang ZHANG, Bin XIE. Application Research on Q460 High-strength Steel Tube in Transmission Line Project[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(4): 88-94. doi: 10.16516/j.gedi.issn2095-8676.2017.04.017
Citation: Ting ZENG, Xiaoming GAO, Zhe WU, Liangliang ZHANG, Bin XIE. Application Research on Q460 High-strength Steel Tube in Transmission Line Project[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(4): 88-94. doi: 10.16516/j.gedi.issn2095-8676.2017.04.017

Application Research on Q460 High-strength Steel Tube in Transmission Line Project

doi: 10.16516/j.gedi.issn2095-8676.2017.04.017
  • Received Date: 2017-06-05
  • Publish Date: 2020-07-18
  • With the increasingly narrow power corridor, the tower type is developing to multi-loop and high load, and the application of high strength steel is imminent. Based on a 500 kV project, aimed at high wind speed, multi loop conditions, this paper analyzed and compared the tower type in many aspects, such as the domestic and foreign application type, material, structure arrangement, full-scale test, engineering measures. The results show that the weight of the steel tube can be reduced effectively by using Q460. The stiffness of the tower is good and the deflection is small. The test tower strength and construction measure meet the design requirements, and have certain safety reserves. Therefore, under the large load conditions, the application of Q460 high strength steel tube has obvious economic and social benefits.
  • [1] 郭咏华,张天光,王经运. Q460高强钢试验研究及电力工程应用 [M]. 北京:中国电力出版社,2010.

    GUO Y H, ZHANG T G, WANG J Y. Experimental study and electrical engineering application of Q460 high-strength steel [M]. Beijing:China Electric Power Press,2010.
    [2] 曹现雷,郝际平,张天光. 新型Q460高强度钢材在输电铁塔结构中的应用 [J]. 华北水利水电学院学报,2011,32(1):79-82.

    CAO X L, HAO J P, ZHANG T G. Engineering application of new high-strength steel Q460 in transmission tower [J]. Journal of North China Institute of Water Conservancy and Hydroelectric Power,2011,32(1):79-82.
    [3] 范金华,薛敏,傅鹏程. Q460高强钢管在500 kV练塘—泗泾输电线路工程中的应用 [J]. 华东电力,2010,38(7):1040-1042.

    FAN J H XUE M, FU P C. Application of Q460 high-strength steel tube in the 500 kV Liantang-Sijing power transmission line project [J]. East China Electric Power,2010,38(7):1040-1042.
    [4] 刘盼. 高强等边角钢极限承载力及稳定性试验与分析 [D]. 重庆:重庆大学,2009.

    LIU P. Experiments and analysis on the ultimate bearing capacity and stability of high-strength equilateral-angle steel member [D]. Chongqing:Chongqing University,2009.
    [5] 中华人民共和国国家发展和改革委员会. 铁塔用热轧角钢:YB/T 4163—2007 [S]. 北京:冶金工业出版社,2007.

    The National Development and Reform Commission of the People's Republic of China. Hot rolled steel aangles for tower structure: YB/T 4163—2007 [S]. Beijing:Metallurgical Industry Press,2007.
    [6] 中国国家标准化管理委员会. 低合金高强度结构钢:GB/T 1591—2008 [S]. 北京:中国标准出版社,2008.

    China National Standardization Administration Commission. High strength low alloy structural steels:GB/T 1591—2008 [S]. Beijing:China Standard Press,2008.
    [7] 中国国家标准化管理委员会. 输电线路铁塔制造技术条件:GB/T 2694—2010 [S]. 北京:中国电力出版社,2013.

    China National Standardization Administration Commission. specificaton of manufacturing for transmission line tower:GB/T 2694—2010 [S]. Beijing:China Electric Power Press,2013.
    [8] 国家能源局. 架空线路钢杆塔结构荷载试验:DL/T 899—2012[S]. 北京:中国电力出版社,2012.

    National Energy Administration. Loading tests on tower and pole structures of overhead line:DL/T 899—2012 [S]. Beijing:China Electric Power Press,2012.
  • 通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

Figures(6)  / Tables(10)

Article Metrics

Article views(185) PDF downloads(16) Cited by()

Related

Application Research on Q460 High-strength Steel Tube in Transmission Line Project

doi: 10.16516/j.gedi.issn2095-8676.2017.04.017

Abstract: With the increasingly narrow power corridor, the tower type is developing to multi-loop and high load, and the application of high strength steel is imminent. Based on a 500 kV project, aimed at high wind speed, multi loop conditions, this paper analyzed and compared the tower type in many aspects, such as the domestic and foreign application type, material, structure arrangement, full-scale test, engineering measures. The results show that the weight of the steel tube can be reduced effectively by using Q460. The stiffness of the tower is good and the deflection is small. The test tower strength and construction measure meet the design requirements, and have certain safety reserves. Therefore, under the large load conditions, the application of Q460 high strength steel tube has obvious economic and social benefits.

Ting ZENG, Xiaoming GAO, Zhe WU, Liangliang ZHANG, Bin XIE. Application Research on Q460 High-strength Steel Tube in Transmission Line Project[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(4): 88-94. doi: 10.16516/j.gedi.issn2095-8676.2017.04.017
Citation: Ting ZENG, Xiaoming GAO, Zhe WU, Liangliang ZHANG, Bin XIE. Application Research on Q460 High-strength Steel Tube in Transmission Line Project[J]. SOUTHERN ENERGY CONSTRUCTION, 2017, 4(4): 88-94. doi: 10.16516/j.gedi.issn2095-8676.2017.04.017
  • 多年来,我国输电铁塔钢材以Q235、Q345热轧角钢和钢管为主,近年来Q420和Q460逐渐开始应用。但与先进国家相比,我国输电铁塔材质单一、强度值偏低,致使塔重偏大、经济效益和社会效益偏低[1]。随着电力需求的不断增长,社会的日益发展,输电线路向高电压、大容量、多回路发展,电力走廊也日趋狭窄,导致塔型变大,承受荷载也越来越大,对输电塔的新材料、新工艺的推广和应用越来越迫在眉睫[2,3]。使用Q460高强钢不但可以减轻塔重、减少加工和施工难度、降低造价、节约能源、利于环保,而且还可以提高我国杆塔结构设计水平、加工水平和在国际市场上的竞争力[4]

    汕头500千伏海门电厂扩建3-4号机组送出工程,长约38.5 km。设计风速为37 m/s和39 m/s,导线为4×JL/LB1A-630/45。工程设计风速高、导线截面大,且含有较长公里数的500/220 kV混压四回,因此采用Q460高强钢管能有效减轻塔重,减少工程投资。

  • 国外的钢材标准与我国大体相同,但对于Q390~Q460强度级别的高强度钢材,国外发达国家的应用已经非常普遍。日本在20世纪90年代相继建成的1 000 kV双回路线路中,主材采用SS55或STK55钢管(屈服强度415 MPa),《日本架空送电规程》(JEAC 6001—2000)又将钢材屈服强度提高到520 MPa(JS690S钢);欧美国家大多采用A36、G50、GR65(屈服强度为450 MPa),《美国输电铁塔设计导则》的钢材强度已达到686 MPa。

    我国现行规范,如《铁塔用热轧角钢》[5]、《低合金高强度结构钢》[6],都明确规定了Q420、Q460牌号钢板/型钢/角钢的化学成分和力学性能。《钢结构设计规范》(2012征求意见稿)中也增列了Q460钢种。这些规程规范都为高强钢的制造和工程应用提供了依据。目前Q420钢已经普遍应用于输电杆塔中,国内许多塔厂也有了一定的加工经验。Q460钢材也在国内的少量工程中得到试点应用,如500 kV平顶山至洛阳南输电线路工程,首次应用了Q460高强角钢[1];500 kV练塘至泗泾紧缩型双回路首次采用了Q460高强钢管塔[4]

  • GB/T 1591和YB/T 4163给出的Q345、Q420、Q460钢材的力学性能如表1表2所示。

    牌号 质量等级 屈服强度/(N/mm2) 抗拉强度/(N/mm2) 断后伸长率 冲击试验(V型缺口)AKV,J 180°弯曲试验d=弯曲直径/mm a=试样厚度/mm
    ≦16 mm +20 ℃ 0 ℃ -20 ℃ -40 ℃ 厚度/mm
    不小于 不小于 ≦16 mm >16~35
    Q345T A 345 325 470~630 21         d=2a d=3a
    B 21 34      
    C 22   34    
    D 22     34  
    Q420T A 420 400 520~680 18         d=2a d=3a
    B 18 34      
    C 19   34    
    D 19     34  
    E 19       27
    Q460T A 460 440 550~720 17         d=2a d=3a
    B 17 34      
    C 17   34    
    D 17     34  
    E 17       27

    Table 1.  The type and performance of the angle steel specified in “YB/T 4163”

    牌号 质量等级 屈服强度/(N/mm2) 抗拉强度/(N/mm2) 断后伸长率 冲击试验(V型缺口)AKV,J(12~150 mm) 180°弯曲试验d=弯曲直径/mm a=试样厚度/mm
    ≦16 mm >16~40 mm +20 ℃ 0 ℃ -20 ℃ -40 ℃ 厚度/mm
    不小于 ≦40 mm ≦40 mm 不小于 ≦16 >16~100
    Q345 A 345 335 470~630           2a 3a
    B 20 34      
    C     34    
    D 21     34  
    E         34
    Q420 A 420 400 520~680           2a 3a
    B   34      
    C 19   34    
    D       34  
    E         34
    Q460 C 460 440 550~720     34     2a 3a
    D 17     34  
    E         34

    Table 2.  The type and performance of steel plate, section steel specified in “GB/T 1591”

  • 根据《110~750架空输电线路设计规范》和《钢结构设计规范》(2012版,征求意见稿),给出钢材和螺栓的强度设计值如表3表4所示。

    牌号 厚度或直径 抗拉、抗压和抗弯 抗剪
    Q345 ≤16 mm 310 180
    >16~40 mm 295 170
    Q420 ≤16 mm 380 220
    >16~40 mm 360 210
    Q460 ≤16 mm 410 235
    >16~40 mm 390 225

    Table 3.  Strength design value of steel N/mm2

    类别 材料 抗拉 抗剪
    镀锌粗制螺栓(C级) 4.8 200 170
    6.8 300 240
    8.8 400 300
    10.9 500 380

    Table 4.  The strength design value of bolted N/mm2

  • 以双回路直线塔和四回路混压耐张塔为例,对主材采用Q345和Q460材质进行技术方案比较。

  • 设计输入条件如表5所示,单线图如图1图2所示。

    塔型 5F2W8-ZGV2-48
    导线 4×JL/G1A-630/45
    地线 LBGJ-150-40AC
    设计风速/(m·s-1) 37(10 m高)
    水平档距/m 509
    垂直档距/m 750

    Table 5.  The design conditions for 5F2W8-ZGV2

    Figure 1.  Single line chart of ZGV2

    Figure 2.  Single line chart of JS5732

    对主材采用Q345和Q460进行计算比较,如表6所示。可以看出:

    材质 Q345 Q460
    塔腿主材管径×壁厚/mm ∅457×10 ∅356×10
    法兰盘直径/mm 820 640
    利用率/% 99 95
    计算重/t 50.3 46.2
    根开/m 15.04 15.04
    长期挠度/mm 35.6,0.5‰ 37.2,0.5‰
    最大挠度/mm 709.2,9.3‰ 739.3,9.7‰

    Table 6.  Comparison of the results of Q345 and Q460 for 48 m

    1)采用Q345或Q460,塔身刚度都较好,杆身的长期挠度和最大挠度均很小,在规范要求限值以内。

    2)主管的最大直径和法兰盘直径较加工限值小很多。

    3)采用Q460钢材,塔重较Q345有明显的降低,大约少8.8%。

  • 设计输入条件如表7所示。单线图如图2所示。

    塔型 JS5732
    导线 4×JL/G2A-720/50/4×JL/G1A-300/40
    地线 LBGJ-150-40AC
    设计风速/(m·s-1) 37(10 m高)
    转角度数/(°) 30~60
    水平档距/m 250/150
    垂直档距/m ±450/±250

    Table 7.  The design conditions for JS5732

    对主材采用Q345和Q460进行计算比较,如表8所示。可以看出:

    牌号 Q345 Q460
    塔腿主材管径×壁厚/mm ∅914×18 ∅762×16
    法兰盘直径/mm 1 500 1 250
    利用率/% 100% 98%
    计算重/t 130.0 112.4
    根开/m 14.75 14.75
    长期挠度/mm 44.2,0.6‰ 46.7,0.6‰
    最大挠度/mm 883.8,11.1‰ 935.9,11.8‰

    Table 8.  Comparison of the results of Q345 and Q460 for 30 m

    1)采用Q345或Q460,塔身刚度都较好,杆身的长期挠度和最大挠度均很小,在规范要求限值以内。

    2)主管的最大直径和法兰盘直径较加工限值小很多。

    3)采用Q460钢材,塔重较Q345有明显的降低,大约少15.6%。

  • 双回路和四回路杆塔采用钢管塔方案(塔身采用钢管、横担采用角钢)。角钢采用Q235B、Q345B、Q420B三种钢材,钢管采用Q235B、Q345B、Q460C三种钢材。

    地脚螺栓采用42CrMo合金结构钢。

  • 1)杆塔按全方位长短腿计算,正面满足30°地形要求。

    2)塔腿主斜材夹角不宜小于23°,斜材与水平面夹角不宜小于25°。

    3)塔腿辅助材采用合理的布置方式,增强对主斜材的支撑作用;塔腿斜材刚度应与主材匹配。

    4)塔身斜材与水平面的夹角取30°~45°为宜,不得大于50°。

    5)导线横担主材夹角不宜小于18°,耐张塔地线横担主材夹角不宜小于15°。

  • 1)主材的长径比小于12、斜材夹角小于24°时,应结合所在的部位、约束情况、长细比(长径比)、径厚比以及应力利用情况,综合考虑钢管端部弯矩的不利影响。

    2)钢管按照“同一规格采用同一材质”的原则应用。当受力材(钢管)之间的夹角<25°时,支撑该受力材的辅助材的承载力应适当提高或通过试验确定。

    3)铁塔的斜材设计应按不同的塔型布置,参照DL/T 5154—2012的要求,计算埃菲尔效应。

  • 1)结合本工程荷载大的特点,大直径钢管主材比例较高。根据测算结果和市场采购特点,建议管径300 mm以上时采用Q460高强钢,钢板卷制。

    2)针对Q460钢管焊接质量较难把控及切割打孔较难的特点[7],建议Q460钢管主材节点法兰仍采用Q345钢。由此法兰板及法兰肋板与Q460主管焊接仍采用Q345钢对应焊接要求,大大降低焊接工艺难度。Q460高强焊缝仅为卷管焊接焊缝,采用卷管自动焊机焊接,焊接质量有较高保证,卷管焊缝为非主受力焊缝,焊接质量对构件承载能力影响较小。同时由于法兰强度与材料强度的1/2次方成正比,材料强度提升对法兰强度提升影响较小。因此采用Q345法兰较Q460法兰不仅焊接质量有较高保证,且经济效益也无明显降低。

    3)Q460主材钢管径厚比控制在45以下以降低局部稳定对钢管承载力的影响。

  • 由于Q460高强钢管塔的设计、运行经验很少,因此除了在设计上采用先进的理论和软件计算外,还应进行试验验证,以检验其在各种主要荷载工况下受力杆件理论计算值和实际受力值的符合性,验证塔型设计方案的合理性以及塔型结构、节点构造和连接法兰的安全可靠性。为此,于2016年4月18日至—20日在中国电力科学研究院良乡试验基地,对5F2W8-ZGV2-35钢管塔行了真型试验。

  • 试验塔的设计执行DL/T 5154—2012和DL/T 5254—2010,并参考了类似工程的设计、施工和运行经验。计算软件为“自立式铁塔内力分析软件”(TTA)和自编的一些计算程序。设计条件如表9所示。

    塔型 5F2W8-ZGV2-35
    导线 4×JL/G1A-630/45
    地线 LBGJ-150-40AC
    设计风速/(m·s-1) 37(10m高)
    覆冰/mm 0
    水平档距/m 572
    垂直档距/m 750
    腿部主材规格/mm ϕ356×10
    全高/m 66.4
    铁塔重量/t 55.0

    Table 9.  The design conditions for Test tower

    试验塔单线图如图3所示。

    Figure 3.  single line diagram of Test tower ZGV2-35

  • 试验塔设计工况共63个,选取了7个控制工况进行试验[8],如表10所示。其中工况1-6的加荷级别为:0-50%-75%-90%-95%-100%-0;工况7的加荷级别为:0-50%-75%-90%-95%-100%-105%- 110%-115%-120%-0。

    工况号 工况名 试验目的
    1 同时断右地线和右上导线 地线横担的承载力和变形情况
    2 同时断右上、中导线 检验铁塔在事故工况下的承载力和变形情况
    3 起吊右下导线、其它导线均已装(地线已装) 导线横担的承载力和变形情况
    4 锚右下导线、其它导线均已锚 检验铁塔在安装工况下的承载力和变形状况
    5 90°大风计算 90°大风的承载力状况和变形情况
    6 0°大风计算 0°大风的承载力状况和变形情况
    7 60°大风计算(超载) 60°大风的承载力状况和变形情况

    Table 10.  The test conditions

  • 试验塔的变形测点和应变布置如图4图5所示。位移测点共12个,以1、2、…、12编号;应变测点共20个,每个测点贴应变片3~4个不等,共计70个。

    Figure 4.  Displacement observation point layout

    Figure 5.  Strain observation point layout

    试验顺利通过表10中7个工况的测试,试验现场加载情况如图6所示,其中60°的大风超载120%。试验表明,该试验塔的强度和刚度均符合设计要求,并有一定的安全储备。

    Figure 6.  Test tower in loading

  • 通过对试验数据和现场情况分析,得到以下结论和建议,供工程设计参考:

    1)使用Q460高强钢材,能够满足输电线路钢管塔的设计要求,同时可降低单基塔重,建议在大风区、大导线、多回路输电线路工程中应用。

    2)大风工况下的最大挠度试验值为733 mm,9.7‰。与理论计算值相差无几,说明钢管塔所采用法兰连接等构造方式有较好刚度。

    3)试验超载致120%,杆底主管并无明显的屈服破坏。说明设计是安全可靠的,并有一定的裕度。

  • 对于本工程而言,双回路和四回路塔,较大直径钢管的比例和规格都较多,采用Q460高强钢管后,塔重降低的绝对值和相对比例都较大。

    根据测算结果,对本工程双回路塔,采用Q460后,较Q345减少塔重约7%~10%;四回路塔,减少塔重约10%~15%。本工程共有83基采用Q460高强钢,塔重共计12 748 t。按平均减轻塔重12.4%计算,本工程节约钢材共1 804 t。按综合单价Q345钢材9 800元/ t、Q460钢材10 200元/ t来计算,采用Q460钢材,可以节省铁塔投资约1 258万,经济效益明显。

    除节省钢材外,也有效降低了铁塔材料规格及其相应挡风面积,从而降低基础作用力与基础造价。依据测算,应用Q460高强钢管,能降低基础工程量约3.1%,节省基础工程造价约300万元。

  • 据调查,每炼1 t钢材需要燃烧标准煤约0.65 t,每燃烧1 t标准煤,产生CO2约2.62 t,SO2约8.5 kg,氮氧化物约7.4 kg。

    本工程共减少钢材约1 804 t,相应减少标准煤燃量1 173 t,减排CO2约4 276 t、SO2约15 t,氮氧化物13 t。同时可降低基础材料水泥用量约300 t,减少砂石用量约1 500 t,节能减排与环保效益显著。

  • 1)国内关于Q460高强钢管塔的应用还很少,缺乏设计、加工、运行经验。

    2)高风速、大导线、多回路条件下,采用Q460高强钢管,较Q345能减轻塔重约7%~15%。且塔身刚度较好,杆身的长期挠度和最大挠度均很小,满足规范要求。

    3)根据目前材料的市场供应、质量和价格,对于钢管组合塔,主材管径大于300 mm规格时,建议采用Q460C级材料。其中法兰仍然采用Q345钢材。

    4)试验塔在7个控制工况下,实测的位移和应变值与理论值符合的较好,证明设计推导符合杆塔实际受力。试验超载致120%,主管并无明显的屈服破坏,钢管塔各部件未见异常,说明设计是安全可靠的。

    5)本工程采用Q460高强钢管,具有明显的经济效益和社会效益。

Reference (8)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return